Voltage drop summary
Voltage at the device Within limit
11.36 V
5.3% worst voltage drop (0.64 V)
- Supply load
- 2 A of 4 A usable (within rating)
- Remaining
- 2 A left
- Output
- 24 W
- Reserve
- 20% (1 A)
Device groups
| Group | Devices | Load each | Wire | Run | Drop · at device | Smallest wire | Longest run |
|---|---|---|---|---|---|---|---|
| Device group 1 | 4 | 0.5 A | 18 AWG | 100 ft | 5.3% · 11.36 V | 20 AWG | 187 ft |
Settings
- Supply
- 12 V DC, 5 A rated
- Drop limit
- 10%
- Wire sizes
- AWG, copper
Notes
- Each device has its own run from the supply. The drop is the current times the resistance of both conductors, for copper at 20 °C; warm cable and copper-clad aluminium (CCA) drop more.
- Within the drop limit doesn't confirm a device will run: check the voltage at the device against the minimum input voltage on its datasheet.
- The smallest wire and longest run are the thinnest listed size and the longest length that keep the drop within the limit.
- Within the rating less the reserve is OK; into the reserve is a caution; above the full rating is over.